Refine your search
Collections
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z All
Grace Kanmani Prince, P.
- LabVIEW Based Abnormal Muscular Movement and Fall Detection Using MEMS Accelerometer during the Occurrence of Seizure
Abstract Views :219 |
PDF Views:0
Authors
Affiliations
1 Sathyabama University, Chennai, IN
2 St. Peter’s College of engineering and Technology, Chennai, IN
1 Sathyabama University, Chennai, IN
2 St. Peter’s College of engineering and Technology, Chennai, IN
Source
Indian Journal of Science and Technology, Vol 7, No 10 (2014), Pagination: 1625-1631Abstract
The manifestation of seizure in patients can be in the form of abnormal muscular movement occurring at the extremities and it can cause sudden fall to the patients which can lead to injuries. MEMS accelerometer MPU6050 is used to acquire the signals from the extremities to detect abnormal movements and sudden fall. The signals are received through an interfacing device named Arduino Uno and are processed using LabVIEW software. The Wavelet transform is used for detecting the changes in movement of the extremity and a thresholding technique is used for seizure detection and fall detection. Once a seizure or fall is detected then a message is sent to the caretaker through GSM.Keywords
Abnormal Muscular Movement, Fall Detection, Mems Accelerometer, Seizure, Wavelet Transform- Study of Object Detection in Sonar Image using Image Segmentation and Edge Detection Methods
Abstract Views :145 |
PDF Views:0
Authors
Affiliations
1 Department of Electronics and Control Engineering, School of Electrical and Electronics Engineering,Sathyabama University, Rajiv Gandhi Salai, Jeppiaar Nagar, Chennai - 600 119, Tamil Nadu, IN
2 ManakulaVinayagar Institute of Technology, Kalitheerthalkuppam, Puducherry – 605107, IN
3 Department of Electronics and Control, Faculty of Electronics, Sathyabama University, Rajiv Gandhi Salai, Jeppiaar Nagar, Chennai - 600 119, Tamil Nadu, IN
1 Department of Electronics and Control Engineering, School of Electrical and Electronics Engineering,Sathyabama University, Rajiv Gandhi Salai, Jeppiaar Nagar, Chennai - 600 119, Tamil Nadu, IN
2 ManakulaVinayagar Institute of Technology, Kalitheerthalkuppam, Puducherry – 605107, IN
3 Department of Electronics and Control, Faculty of Electronics, Sathyabama University, Rajiv Gandhi Salai, Jeppiaar Nagar, Chennai - 600 119, Tamil Nadu, IN
Source
Indian Journal of Science and Technology, Vol 9, No 42 (2016), Pagination:Abstract
The technique which uses sound waves to navigate, communicate or detect objects under the surface of sea water is commonly known as SONAR. Recognition and interpretation of objects is an important task in the sonar image processing. The resolution of the examined image is not adequate to classify the objects separately and is mainly affected by the multiplicative noise. The main focus of this work is to implement post-processing technique by entropy filter along with morphological processing for object identification. Relative analysis on the observed results with existing techniques of edge detection implies that the proposed work improves the result of target identification. Furthermore, removal of noise in the sonar image is also discussed in this paper.Keywords
Edge Detection Operators, Entropy Filter, Morphological Processing, Object Recognition, SONAR.- Analysis of Non-Invasive Methods to Diagnose Blood Glucose Level- A Survey
Abstract Views :187 |
PDF Views:0
Authors
Affiliations
1 Sathyabama Institute of Science and Technology, Department of Electronics and Communication, Rajiv Gandhi Road, Chennai 600118, IN
1 Sathyabama Institute of Science and Technology, Department of Electronics and Communication, Rajiv Gandhi Road, Chennai 600118, IN
Source
Research Journal of Pharmacy and Technology, Vol 12, No 6 (2019), Pagination: 3105-3108Abstract
Diabetes or otherwise known as blood glucose level among the people is a serious issue to be considered nowadays. There are three types of diabetes namely TYPE 1 which occurs due to destruction of beta cells, TYPE 2 which occurs due insufficient secretion of insulin into the cells by pancreas and the third one GESTATIONAL type which occurs during pregnancy. To detect blood glucose level at present there are device like glucometer which is handheld and can be detected by the people in home itself. The other one is the professional testing method in hospitals. The drawback in these two methods is that they are invasive type of detection which includes needle incision which may lead to pain among the patients, the patients may feel uncomfortable or they may get panic. This paper deals with the study of non-invasive methods of detecting diabetes which will be helpful to extend the work in future for both the patient and also to the country since the invasive methods are considered the costly one.Keywords
Diabetes, Blood Glucose Level, Non-invasive Methods, Near Infrared Spectroscopy (NIR), Glucose Concentration, Photoacoustic Spectroscopy (PAS).References
- J. L. Smith, The Pursuit of Non-invasif Glucose: Hunting the Deceitful Turkey, Third Edition: Revised and Expanded, 2013.
- K.-S. C. T. K. W. J. W. C. Chi-Fuk So, Recent advances in noninvasive glucose monitoring, Dove Press Journal, 2012.
- Savage, M.B., Kun, S., Harjunmaa, H., Peura, R.A. Development of a non-invasive blood glucose monitor: Application of artificial neural networks for signal processing. In Proceedings of the IEEE 26th Annual Northeast Bioengineering Conference, Storrs, CT, USA, 9 April 2000; pp. 29–30.
- "Blood function and composition". Internet: http://www.virtualmedicalcentre.comlan atomy Iblood -function -andcompositionl30, Sept. 15, 20 I 0 [Oct. 29, 20 II].
- H.P. Schwan, Electrical Properties of Blood and its Constituents: Alternating Current Spectroscopy. Blut 46: 185-197, 1983.
- Anas, M.N, NurunN. K, A.N. Noral, Normahira, M, Non-invasive blood glucose measurement, IEEE EMBS International Conference on Biomedical Engineering and Sciences, Dec 2012, pp. 540-507.
- Rolamjaya Hotmartua, Pujianto Wira Pangestu, Hasballah Zakaria, Yoke Saadia Irawan, Noninvasive Blood Glucose Detection Using Near Infrared Sensor, IEEE 2015, PP. 687-692.
- Praful P. Pai, Pradyut K. Sanki, Sudeep K. Sahoo, Arijit De, Sourangshu Bhattacharya, and Swapna Banerjee, Cloud Computing-Based Non-Invasive Glucose Monitoring for Diabetic Care, IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS–I: REGULAR PAPERS, VOL. 65, NO. 2, FEBRUARY 2018, PP NO.663-676.
- P. P. Pai, P. K. Sanki, S. Sarangi, and S. Banerjee, Modelling, verification, and calibration of a photoacoustics based continuous non-invasive blood glucose monitoring system, Rev. Sci. Instrum., vol. 86, no. 6, p. 064901, 2015.
- S. Camou, Y. Ueno, and E. Tamechika, Isothermic determination of aqueous solution glucose concentration in low mg/dL range by C Wphotoacoustic-based protocol, Sens. Actuators B, Chem., vol. 185, pp. 568–574, Aug. 2013.
- S. Camou, Y. Ueno, and E. Tamechika, Detection of aqueous glucose based on a cavity size- and optical-wavelength-independent continuous-wave photoacoustic technique, Anal. Chem., vol. 84, no. 11, pp. 4718–4724, 2012.
- M. A. Pleitez, T. Lieblein, A. Bauer, O. Hertzberg, H. von Lilienfeld-Toal, and W. Mäntele, Windowless ultrasound photoacoustic cell for in vivo mid-IR spectroscopy of human epidermis: Low interference by changes of air pressure, temperature, and humidity caused by skin contact opens the possibility for a non-invasive monitoring of glucose in the interstitial fluid, Rev. Sci. Instrum., vol. 84, no. 8, p. 084901, 2013.
- M. A. Pleitez, T. Lieblein, A. Bauer, O. Hertzberg, H. von Lilienfeld-Toal, and W. Mäntele, In vivo noninvasive monitoring of glucose concentration in human epidermis by midinfrared pulsed photoacoustic spectroscopy, Anal. Chem., vol. 85, no. 2, pp. 1013–1020, 2013.
- J. Kottmann, J. M. Rey, J. Luginbühl, E. Reichmann, and M. W. Sigrist, Glucose sensing in human epidermis using mid-infrared photoacoustic detection, Biomed. Opt. Exp., vol. 3, no. 4, pp. 667–680, 2012.
- A. Rosencwaig, Photoacoustic spectroscopy of biological materials, Science, vol. 181, no. 4100, pp. 657–658, 1973.
- Catherine Todd, Paola Salvetti, Katy Naylor and Mohammad Albatat, Towards Non-Invasive Extraction and Determination of Blood Glucose Levels, Bioengineering 2017, 4, 82; doi:10.3390/bioengineering4040082.
- Wallenius, N. State-of-the-Art and User Requirements of Blood Glucose Measurement: Devices, Softwareand Services. Master’s Thesis, iAalto University, Helsinki, Finland, 20 January 2017.
- Y C Jiang1, M J Sun2 and R J Xiong, Design of a noninvasive diabetes detector based on acetone recognition, IOP Conf. Series: Journal of Physics: Conf.series 1206(2018). pp.no 1-8.
- Sulway M, Malins J 1970 Acetone in diabetic ketoacidosis The Lancet, 296(7676): 736-740.
- Yamane N, Tsuda T, Nose K, Yamamoto A, Ishiguro H, Kondo T 2005, Relationship between skin acetone and blood beta-hydroxybutyrate concentrations in diabetes Clinica Chimica, Acta, 3651-2.
- ShyqyriHaxha and Jaspreet Jhoja, Optical Based Noninvasive Glucose Monitoring Sensor Prototype, IEEE Photonics Journal, Vol. 8, No. 6, December 2016.
- S. Yao and Y. Zhu, Wearable multifunctional sensors using printed stretchable conductors made of silver nanowires, Nanoscale vol. 6, pp. 2345–2352, 2014.
- I. Mamkin, S. Ten, S. Bhandari, and N. Ramchandani, Real-time continuous glucose monitoring in the clinical setting: The good, the bad, and the practical, J Diabetes Sci. Technol. , vol. 2, no. 5, pp. 882–889, 2008.
- ATR spectroscopy-An introduction to atr spectroscopy, Andor.com, (2015). [Online]. Available: http://www.andor. com/learning-academy/absorption-transmission-reflection-spectroscopy-an-introduction-to-absorption-transmissionreflection-spectroscopy.
- Shintaro Kurasawa, Shouhei Koyama, ID, Hiroaki Ishizawa, Keisaku Fujimoto and Shun Chino, Verification of Non-Invasive Blood Glucose Measurement Method Based on Pulse Wave Signal Detected by FBG Sensor System, Sensors 2017, 17, 2702.pp no 1-13.